Sunday, January 19, 2014

10. Wiring and Safety Components for PV Solar Systems

Main Subjects
  • Type of cables and Characteristics used in Solar PV Systems.
  • Selection of Conduit
  • Disconnect Switches
  • Selection of Fuse/ Circuit Breaker
  • Ground Fault Protection
  • Labeling Requirements
Type of cables and Characteristics used in Solar PV Systems.
  1. Underground Service Entrance Cable - for outdoor applications. not designed for fire ratings.
  2. External Wiring - 
  3. Building Wiring (Internal Applications) - THHN, THWN - Heat Resistant Thermoplastic - doent run outside building. No sunlight resistant Characteristics. 
  4. Battery wiring - Moister Resistant Thermoset (EHW) Heat Resistant themoplastic, Flexible wiring is another choice, make sure terminals and legs are designed for battery use.
  5. Grounding Wiring - Bare copper or Insulated copper conductor.
Selection of Conduit

  • Selection - Depends up on the location (dry/wet)
  • Temperature of Installation.


  • Flexible and Rigid
  • Metallic Conduit
  • Non-Metallic Conduit

EMT(Electric Metallic Conduit) used for long run, less expensive, inside & outside application

FMT(Flexible Metallic conduit) Used for indoor application, for shot run ,more cost, less labor.

Non-Mettalic conduit - Rigid PVC, - Used for underground / Outside building.

Disconnect Switches
As per Utility requirements, PV Circuit and Inverter output should be lockable disconnect switch.

One Lockable Disconnect switch should be near the meter and should be visible and utility can access 24/7 .
will be operated by utility service person.

Selection of Fuse/ Circuit Breaker
For High Voltage DC Applications, the Fuse should be Selected accordingly.
Case Study:-

Ground Fault Protection
Is a standard in Grid Tied inverter.
Refer
solarprofessional.com

Labeling Requirements
DC Disconnect.
Utility Power Interconnection Point.
Building Exterior - Should have details of PV Source and all disconnection of the system.

========================================================================
CASE STUDY -1
========================================================================


Cable - A
Reference 690.8A, 690.8B --> Connect from PV Module.

(No of modules (strings) wired in parallel)  X  (Short circuit current-Isc) X  1.25 (safety factor for irradiance)  X  1.25(Cable safety factor)

Cable shall not carry 80% of Max.
Where the maximum Current is expected to continue for 3 Hours or more, considered as continuous load (NEC Code article 100)

Total Safety factor - 1.25x1.25 = 1.56
Isc - 5.5A

Cable Selection for PV - 1.56 X 5.5A = 8.6Amp


Cable - B
Max. Output Current X 1.25 =

Sunday, November 11, 2012

Live Drafting and Design Services


Live Design Services is a leading provider of AutoCAD Design Services Center. We cater to the needs of hundreds of organizations including industrial companies, engineering firms and construction companies.

We Specialized in
Electrical Design and drafting services:

  1. Electrical Site Plans
  2. Electrical, Power and Lighting System plans
  3. Electrical Panel Schedules
  4. Electrical One Line Diagrams
  5. Layouts for lighting showing Lighting fixture, Emergency Lighting etc.
  6. Terminations Diagrams
  7. Control Circuits
  8. LLV/HV electrical devices
  9. Electrical Documentation Services

Other CAD Design Services:
  1. 2D Cad Services
  2. Format conversion
  3. Take-off Sheets from Drawings

Paper to CAD Conversion
Our skilled draftsmen can convert paper drawing into high precision digital formats.We convert all types of drawings including mechanical, architectural, electrical, structural, and plumbing. The drawings are mainly converted into the following formats:

  • TIFF
  • JPEG
  • DWG
  • DXF

Tuesday, August 16, 2011

13. PV Solar System Wiring and Safety Devices

Selection of Cable and Safety devices will play an important role in the budget of the system

AC Voltage drop based on impedance
DC Voltage drop based in resistance
PV Cable Sizing
Maximum current = No of modules (strings) wired in parallel  x the short circuit current Isc x 1.25

OCPD Sizing
Over Current Protection Device
The Conductors are designed for 80% of capacity for 3Hr continuous rating.

OCPD = 1.25 x 1.25 = 1.56-Multiplication factor'

Nominal Voltage - Baseline of measuring Voltage - PV Modules will be availabel @ 12V & 24V modules

Nominal Voltage   - 12Volt
Operating Voltage - 17 to 18Volt




Solar PV System Devices
  • Underground Feeder (UF)—may be used for interconnecting balance-of-systems (BOS) but not recommended for use within battery enclosures; single conductor UF wire may be used to interconnect modules in the array but this type of wire is not widely available.
  • Tray Cable (TC)—multi-conductor TC wire may be used for interconnecting BOS; TC has good resistance to sunlight but may not be marked as such.
  • Service Entrance (SE)—may be used for interconnecting BOS
  • Underground Service Entrance (USE)—may be used for interconnecting modules or BOS; may be used within battery enclosures
  • THHN—indicates wire with heat resistant thermoplastic sheathing; it may be used for interconnecting BOS but must be installed in conduit, either buried or above ground. It is resistant to moisture but should not be used in wet locations.
  • TW—refers to moisture resistant thermoplastic sheathing; it may be used for interconnecting BOS but must be installed in conduit. May be used in wet locations.

Saturday, August 13, 2011

Interior Lighting Design - Calculations

Design calculation of Interior Lighting Design
  1. Basic Technical Terms of Lighting
  2. Formulas for calculations
  3. Step-by step method for calculating Lux level in a room
  4. Case Study
  5. Lamp Data - for a lighting Designer
  6. Light Fixture data - for a lighting Designer
  7. Day Lighting - Factors


Basic Technical Terns of Lighting Design

Flow of Light can be compared with the flow of water

quantity
symbol
unit
Description
Example
luminous flux
Φ
lumen (lm)
total quantity of light emitted per second by a light source
quantity of water passing a given point per second
luminous intensity
I
candela (cd)
concentration of light in a specific direction, radiated per second
intensity of a water jet in a given direction.
illuminance
E
lux (lx)
quantity of light, or luminous flux, falling on a unit area of a surface
amount of (rain)water falling on an area of surface per sec.
luminance
L
Candela/Sq Mtr (cd/m2)
luminous intensity emitted per Unit of area of a surface in a specific direction

Efficacy

lumens per watt
The ratio of lamp luminous flux divided by the power consumed by the lamp
Where control gear is taken into account the unit becomes lumens per circuit watt.

COLOUR RENDERING INDEX (CRI) (of a lamp) - Is a measure of a lamp's colour rendering ability.

COLOUR TEMPERATURE (of a light source) - The temperature of a black body which emits radiation of the same chromaticity as the light source being considered.



Interior Lighting Calculation
Formulas for calculations
F      = initial lamp lumens
L      = length of room
K      =Room Index
N     = number of luminaires
UF   = utilisation factor
W    = width of room
D     = Distance between light source and work plane
Hm  = height of luminaire above working plane
MF  = maintenance factor


How to calculate illuminance?

        (F x n x N x MF x UF)
E = ------------------------------
                    A

How to calculate average illuminance in a room?
                  lm
E(AV) = -----------
                 d x d

How to calculate Room Index?
This takes account of room proportions and height of the luminaire above the 
working plane. It is used to determine the Utilization factor.
         L x W
K =------------------
       (L + W) x Hm

How to calculate average maintenance factor a room?

MF = LLMF x LSF x LMF x RSMF

       lm
I = ----------
     4 x 3.1

LLMF  =  Lamp lumen maintenance factor - the reduction in lumen output after specific burning hours
LSF     =  Lamp survival factor - the percentage of lamp failures after specific burning hours
LMF    = Luminaire maintenance factor - the reduction in light output due to dirt deposited on or in the luminaire
RSMF  = Room surface maintenance factor - the reduction in reflectance due to dirt deposition in the room surfaces 





Step-by Step Method of lighting Design
1. Details required - Length, Ht, Required lux level, details of light fixture, Maintenance and Utility factor
2. Calculate the Lux level requirement

Case Study:-

Example 1.1
The illuminance (E) on the working plane is 500 lux.The reflectance is 50%, calculate the luminance of the working plane.
     L = E x R(p.u.)
        = 500 x .5    = 250 Apostilbs
        = 250 / 3.14 = 80 cd/m2


Lamp Data for Lighting Designer
1. Initial Lumen Output - Lamp Output after 100Hours
2. Lighting Design Lumen Output - After 2000 Hours
3. Color Temperature
4. Color Rendering Index & Color Rendering Group
5. Physical Dimensions
6. Ballast Type - (Standard, Program Start etc, Electronic, etc)
7. Power Rating


Light Fixture Data for Lighting Designer
1. Photometric data
2. Space to Height ratio.
3. Utilization factor
4. Electrical Specifications
5. Mechanical Specifications



Day Light Advantages comparing to artificial light
1.  Healthier and more satisfactory
2.  Economic advantage
3.  Good Color rendering.